This study systematically investigates the role of the pore-to-particle size ratio ( λ=dm/dp ) in determining membrane performance.
First-pass extracted concept
pore-to-particle size ratio (λ = dm/dp)
Aliases
pore-to-particle size ratio, λ
Evidence Snippets
Supporting Sources
Linked Claims
The study establishes a unified framework based on λ for membrane selection and design and shows that targeted functionalization expands the functional range of porous membranes.
The pore-to-particle size ratio λ is a determinant of membrane retention and transmission performance across microfiltration and ultrafiltration.
High retention of at least 95% occurs consistently when λ is less than 0.5 across both microfiltration and ultrafiltration regimes.
As λ increases above 1, transmission dominates, but membrane surface modification can dramatically enhance selectivity.
When λ is much less than 1, flux decline is minimal although flux stability varies widely.